K41C

The K 41C truck mounted concrete pump is the perfect choice for small and medium sites. It is adequate when a relevant delivery capacity is needed: bridges and deep pours, car parking and basements. The pump is equipped with an open loop pumping unit model PU 1506 to ensure maxmium reliability and ease of maintenance even in the hardest conditions.

STRENGHT AND RELIABILITY

Booms on CIFA truck mounted pumps combine robustness and reliability. Each section was designed to have maximum structural resistance, reducing to a minimum areas subject to stress.

VERSATILITY AND FLEXIBILITY

Different boom configurations of CIFA truck mounted pumps guarantee maximum operation, versatility and allow to reach any area of the worksite, even those hardly accessible, guaranteeing rapidity when manoeuvring.

PUMPING GROUP

Completely removable, the pumping group ensures a delicate, continuous and regular flow. This technology guarantees an extremely effective system in pumping different kinds of concrete, with aggregates of every size, reducing – with equal payload – the number of cycles per minute ensuring minor wear and a longer life cycle to the machine.

“S” VALVE

The new 7″ valve guarantees, always, maximum intake performance. The special geometry with different thicknesses allows to have a high anti wear resistance.

WEAR PLATE AND RING

Wear plate and ring are geometrically designed and realized with special materials with specific function of high resistance to abrasions and to stress they undergo due to concrete flow.

BOOM PROPORTIONAL DISTRIBUTOR

Ergonomic hydraulic commands for moving the boom.

RADIO COMMAND

Comfortable and light, it allows remote control of the boom and management of main functions of the machine.

VIBRATOR AND HORN CONTROLLED BY CABLE

External acoustic warning connected by cable to make communication easy between pump operator and mixer operator during use.

ELECTRICAL SYSTEMS CAN BE DISCONNECTED

Electrical systems can be disconnected and allow and easy and fast maintenance.

STABILIZATION DISTRIBUTOR

Commands to stabilize the pump on both sides with emergency stop system easily accessible.

REAR CONTROL PANEL

The control panel is towards the end part of the pump, next to the pumping group.

Placing boom B5RZ38/34
Pumping unit PU1506
Driven by PTO
Chassis 4 axes

Pumping unit technical data

Model PU1506
Max. theorical output m3/h 150
Max. pressure on concrete bar 53
Max. numbers of cycles per min. nr. 29
Conc. cylinders (diam. x stroke) mm 230×2100
Concrete hopper capacity l 550
Hydraulic circuit Open

Placing boom technical data

Model B5RZ 41/36
Pipeline diameter mm 125
Max. vertical reach m 40,1
Max. horizontal distance m 35,8
Min. unfolding height m 7,8
Section numbers 5
1st section opening angle 90
2nd section opening angle 180
3rd section opening angle 180
4th section opening angle 237
5th section opening angle 244
Rotation angle 370
 End hose lenght  m  4

pdf logo
Technical Details